ITECH – IT8000 Series Regenerative DC Electronic Load

ITECH – IT8000 Series Regenerative DC Electronic Load

IT8000 series is a family of high power regenerative electronic loads with compact size. The highly integrated capability enables the e-load to simulate various e-load characteristics, and return the consumed energy back to the grid cleanly, saving costs related to energy consumption and cooling, meanwhile eco-friendly. With modular high power density design, IT8000 provide up to 18kW in 3U space. The power is expandable up to 1152kW by master-slave paralleling and active current sharing. If you move into application of high power UPS, storage battery, PV battery, EV, energy storage system, ITECH can help you with IT8000 series high power regenerative electronic load.

Description

♦ Recover DC energy to local grid with efficiency up to 95%
♦ Stand-alone power up to 144kW, expandable by master-slave parallelling up to 1152kW
♦ Stand-alone input voltage up to 2250V
♦ Stand-alone input current up to 2040A
♦ High power density design provides 18kW in 3U space
♦ Built-in waveform generator, support generating arbitrary waveforms
♦ LIST function, support importing LIST files by USB
♦ Power accumulation function
♦ Battery test function, auto-test function, short circuit test function
♦ With pre-charging function, prevent DC loading current overshoot
♦ Full protection: OVP/OCP/OPP/OTP/UVP, Vsense anti-reverse connection protection, and voltage transient drop protection
♦ Built-in standard USB/CAN/LAN/digital IO interface, and optional
♦ GPIB/Analog&RS232 interfaces
♦ Support SCPI protocol, LabVIEW
♦ Operating mode:CC/CV/CP/CR/CC+CV/CV+CR/CR+CC/CC+CV+CP+CR

*The regenerated power is for local grid purpose, not for public grid purpose
Application
Power regenerative efficiency up to 95%
High energy regenerative efficiency. The IT8000 series has a unique energy regenerative function that can regenerate electrical energy and then directly use it in the plant instead of consuming it in the form of heat. Its conversion efficiency can up to 95%, which not only will greatly reduce the user's electricity cost, but also avoid the use of air conditioning or expensive cooling systems.

High power density
Conventional electronic loads are not only with high energy consumption, but also with very large size and weight. Energy consumption electronic load with 30KW load is at least 24U, it is difficult to transport and the cost is higher. IT8000 series regenerative DC electronic load adopts high power density design of 18kW in only 3U high. Compared to conventional electronic loads, the size for IT8000 series is decreased by 80% under the same output power.

Power accumulation function
IT8000 series regenerative DC electronic load uses the power electronic transformation technology on the premise of completing test power experiment to make output energy of measured power supply regenerative recycled and reused. Through the inside fast sampling of voltage and current, the regenerative power value can be observed on the front panel of IT8000 series, including voltage, frequency and power of each phase, as well as total power, total current regenerative and total historical regenerative power, which makes the energy saving effect much easier. Re-open after power failure, IT8000 series will continue to accumulate the regenerative power value based on the last power off value.

List function
IT8000 series regenerative DC electronic load provides list mode, it can complete the complex arbitrary current change mode accurately and fast, and can synchronize with internal or external signals to complete multi-level loading precision test, which greatly save cost for customers. By editing the step value, pulse width and the slope of each step, IT8000 can generate a variety of complex sequences and help users to complete various loading waveforms test. In the CC mode, IT8000 series can set rising and falling speed.

Battery test function
IT8000 series regenerative DC electronic load simulate battery discharge test under CC mode, and support settable discharge cut-off conditions, such as cut-off voltage, cut-off capacity and cut-off time. When any of the three conditions are met, the discharge test will be stopped. Moreover, the battery voltage, discharge time and the discharged capacity can be observed during the test, which reflects the reliability of the battery and its remaining life.

Patented parallel technology
Advantage:
♦ IT8000 has adopted ITECH parallel technology
♦ All the function and performance will be the same as standalone unit
♦ No need to calibrate after paralleling
♦ Fiber transmission, good for anti-interference
♦ Digital paralleling, fully insulated, good for protecting DUT

Multi-channel independent control, maximum 256 channels
IT-M3300 series is provided with independent multi-channel design.The channel sequence will be displayed when it combines to be a multi-channel electronic load system. The user can control each unit independently by GUI software when connecting the communication interface of one unit with PC. Each channel can be operated separately. IT-M3300 series supports maximum 16*16 channels. One 37U rack contains 64 channels. The user may test DUT with different power ranges by parallel connection, making tests more flexible and device usage more efficient.

Full protection
IT8000 series regenerative DC electronic load supports automatic detection the grid state . When grid connection is suddenly disconnected or power down, IT8000 will be turned off. IT8000 series can achieve reliable on-grid function and anti-islanding protection function. IT8000 supports monitoring on DC input voltage and frequency, and supports OCP, OVP, OTP, OPP function.
Model Voltage Current Power Resolution Accuracy Interface Size
IT8005-80-150 80V 150A 5kW 0.001V/0.01A ≤0.02%+0.02%FS/≤0.1%+0.1%FS USB/CAN/LAN/digital IO interface, optional GPIB/Analog&RS232 interfaces 3U
IT8010-80-300 80V 300A 10kW 0.001V/0.01A ≤0.02%+0.02%FS/≤0.1%+0.1%FS USB/CAN/LAN/digital IO interface, optional GPIB/Analog&RS232 interfaces 3U
IT8015-80-450 80V 450A 15kW 0.001V/0.01A ≤0.02%+0.02%FS/≤0.1%+0.1%FS USB/CAN/LAN/digital IO interface, optional GPIB/Analog&RS232 interfaces 3U
IT8030-80-900 80V 900A 30kW 0.001V/0.1A ≤0.02%+0.02%FS/≤0.1%+0.1%FS USB/CAN/LAN/digital IO interface, optional GPIB/Analog&RS232 interfaces 6U
IT8045-80-1350 80V 1350A 45kW 0.001V/0.1A ≤0.02%+0.02%FS/≤0.1%+0.1%FS USB/CAN/LAN/digital IO interface, optional GPIB/Analog&RS232 interfaces 15U
IT8060-80-1800 80V 1800A 60kW 0.001V/0.1A ≤0.02%+0.02%FS/≤0.1%+0.1%FS USB/CAN/LAN/digital IO interface, optional GPIB/Analog&RS232 interfaces 15U
IT8075-80-2040 80V 2040A 75kW 0.001V/0.1A ≤0.02%+0.02%FS/≤0.1%+0.1%FS USB/CAN/LAN/digital IO interface, optional GPIB/Analog&RS232 interfaces 27U
IT8090-80-2040 80V 2040A 90kW 0.001V/0.1A ≤0.02%+0.02%FS/≤0.1%+0.1%FS USB/CAN/LAN/digital IO interface, optional GPIB/Analog&RS232 interfaces 27U
IT8105-80-2040 80V 2040A 105kW 0.001V/0.1A ≤0.02%+0.02%FS/≤0.1%+0.1%FS USB/CAN/LAN/digital IO interface, optional GPIB/Analog&RS232 interfaces 27U
IT8120-80-2040 80V 2040A 120kW 0.001V/0.1A ≤0.02%+0.02%FS/≤0.1%+0.1%FS USB/CAN/LAN/digital IO interface, optional GPIB/Analog&RS232 interfaces 27U
IT8006-300-75 300V 75A 6kW 0.01V/0.01A ≤0.02%+0.02%FS/≤0.1%+0.1%FS USB/CAN/LAN/digital IO interface, optional GPIB/Analog&RS232 interfaces 3U
IT8012-300-150 300V 150A 12kW 0.01V/0.01A ≤0.02%+0.02%FS/≤0.1%+0.1%FS USB/CAN/LAN/digital IO interface, optional GPIB/Analog&RS232 interfaces 3U
IT8018-300-225 300V 225A 18kW 0.01V/0.01A ≤0.02%+0.02%FS/≤0.1%+0.1%FS USB/CAN/LAN/digital IO interface, optional GPIB/Analog&RS232 interfaces 3U
IT8036-300-450 300V 450A 36kW 0.01V/0.01A ≤0.02%+0.02%FS/≤0.1%+0.1%FS USB/CAN/LAN/digital IO interface, optional GPIB/Analog&RS232 interfaces 6U
IT8054-300-675 300V 675A 54kW 0.01V/0.1A ≤0.02%+0.02%FS/≤0.1%+0.1%FS USB/CAN/LAN/digital IO interface, optional GPIB/Analog&RS232 interfaces 15U
IT8072-300-900 300V 900A 72kW 0.01V/0.1A ≤0.02%+0.02%FS/≤0.1%+0.1%FS USB/CAN/LAN/digital IO interface, optional GPIB/Analog&RS232 interfaces 15U
IT8090-300-1125 300V 1125A 90kW 0.01V/0.1A ≤0.02%+0.02%FS/≤0.1%+0.1%FS USB/CAN/LAN/digital IO interface, optional GPIB/Analog&RS232 interfaces 27U
IT8108-300-1350 300V 1350A 108kW 0.01V/0.1A ≤0.02%+0.02%FS/≤0.1%+0.1%FS USB/CAN/LAN/digital IO interface, optional GPIB/Analog&RS232 interfaces 27U
IT8126-300-1575 300V 1575A 126kW 0.01V/0.1A ≤0.02%+0.02%FS/≤0.1%+0.1%FS USB/CAN/LAN/digital IO interface, optional GPIB/Analog&RS232 interfaces 27U
IT8144-300-1800 300V 1800A 144kW 0.01V/0.1A ≤0.02%+0.02%FS/≤0.1%+0.1%FS USB/CAN/LAN/digital IO interface, optional GPIB/Analog&RS232 interfaces 27U
IT8006-500-40 500V 40A 6kW 0.01V/0.001A ≤0.02%+0.02%FS/≤0.1%+0.1%FS USB/CAN/LAN/digital IO interface, optional GPIB/Analog&RS232 interfaces 3U
IT8012-500-80 500V 80A 12kW 0.01V/0.01A ≤0.02%+0.02%FS/≤0.1%+0.1%FS USB/CAN/LAN/digital IO interface, optional GPIB/Analog&RS232 interfaces 3U
IT8018-500-120 500V 120A 18kW 0.01V/0.01A ≤0.02%+0.02%FS/≤0.1%+0.1%FS USB/CAN/LAN/digital IO interface, optional GPIB/Analog&RS232 interfaces 3U
IT8036-500-240 500V 240A 36kW 0.01V/0.01A ≤0.02%+0.02%FS/≤0.1%+0.1%FS USB/CAN/LAN/digital IO interface, optional GPIB/Analog&RS232 interfaces 6U
IT8054-500-360 500V 360A 54kW 0.01V/0.01A ≤0.02%+0.02%FS/≤0.1%+0.1%FS USB/CAN/LAN/digital IO interface, optional GPIB/Analog&RS232 interfaces 15U
IT8072-500-480 500V 480A 72kW 0.01V/0.01A ≤0.02%+0.02%FS/≤0.1%+0.1%FS USB/CAN/LAN/digital IO interface, optional GPIB/Analog&RS232 interfaces 15U
IT8090-500-600 500V 600A 90kW 0.01V/0.1A ≤0.02%+0.02%FS/≤0.1%+0.1%FS USB/CAN/LAN/digital IO interface, optional GPIB/Analog&RS232 interfaces 27U
IT8108-500-720 500V 720A 108kW 0.01V/0.1A ≤0.02%+0.02%FS/≤0.1%+0.1%FS USB/CAN/LAN/digital IO interface, optional GPIB/Analog&RS232 interfaces 27U
IT8126-500-840 500V 840A 126kW 0.01V/0.1A ≤0.02%+0.02%FS/≤0.1%+0.1%FS USB/CAN/LAN/digital IO interface, optional GPIB/Analog&RS232 interfaces 27U
IT8144-500-960 500V 960A 144kW 0.01V/0.1A ≤0.02%+0.02%FS/≤0.1%+0.1%FS USB/CAN/LAN/digital IO interface, optional GPIB/Analog&RS232 interfaces 27U
IT8006-800-25 800V 25A 6kW 0.01V/0.001A ≤0.02%+0.02%FS/≤0.1%+0.1%FS USB/CAN/LAN/digital IO interface, optional GPIB/Analog&RS232 interfaces 3U
IT8012-800-50 800V 50A 12kW 0.01V/0.01A ≤0.02%+0.02%FS/≤0.1%+0.1%FS USB/CAN/LAN/digital IO interface, optional GPIB/Analog&RS232 interfaces 3U
IT8018-800-75 800V 75A 18kW 0.01V/0.01A ≤0.02%+0.02%FS/≤0.1%+0.1%FS USB/CAN/LAN/digital IO interface, optional GPIB/Analog&RS232 interfaces 3U
IT8036-800-150 800V 150A 36kW 0.01V/0.01A ≤0.02%+0.02%FS/≤0.1%+0.1%FS USB/CAN/LAN/digital IO interface, optional GPIB/Analog&RS232 interfaces 6U
IT8054-800-225 800V 225A 54kW 0.01V/0.01A ≤0.02%+0.02%FS/≤0.1%+0.1%FS USB/CAN/LAN/digital IO interface, optional GPIB/Analog&RS232 interfaces 15U
IT8072-800-300 800V 300A 72kW 0.01V/0.01A ≤0.02%+0.02%FS/≤0.1%+0.1%FS USB/CAN/LAN/digital IO interface, optional GPIB/Analog&RS232 interfaces 15U
IT8090-800-375 800V 375A 90kW 0.01V/0.01A ≤0.02%+0.02%FS/≤0.1%+0.1%FS USB/CAN/LAN/digital IO interface, optional GPIB/Analog&RS232 interfaces 27U
IT8108-800-450 800V 450A 108kW 0.01V/0.01A ≤0.02%+0.02%FS/≤0.1%+0.1%FS USB/CAN/LAN/digital IO interface, optional GPIB/Analog&RS232 interfaces 27U
IT8126-800-525 800V 525A 126kW 0.01V/0.1A ≤0.02%+0.02%FS/≤0.1%+0.1%FS USB/CAN/LAN/digital IO interface, optional GPIB/Analog&RS232 interfaces 27U
IT8144-800-600 800V 600A 144kW 0.01V/0.1A ≤0.02%+0.02%FS/≤0.1%+0.1%FS USB/CAN/LAN/digital IO interface, optional GPIB/Analog&RS232 interfaces 27U
IT8018-1500-40 1500V 40A 18kW 0.1V/0.001A ≤0.02%+0.02%FS/≤0.1%+0.1%FS USB/CAN/LAN/digital IO interface, optional GPIB/Analog&RS232 interfaces 3U
IT8036-1500-80 1500V 80A 36kW 0.1V/0.01A ≤0.02%+0.02%FS/≤0.1%+0.1%FS USB/CAN/LAN/digital IO interface, optional GPIB/Analog&RS232 interfaces 6U
IT8054-1500-120 1500V 120A 54kW 0.1V/0.01A ≤0.02%+0.02%FS/≤0.1%+0.1%FS USB/CAN/LAN/digital IO interface, optional GPIB/Analog&RS232 interfaces 15U
IT8072-1500-160 1500V 160A 72kW 0.1V/0.01A ≤0.02%+0.02%FS/≤0.1%+0.1%FS USB/CAN/LAN/digital IO interface, optional GPIB/Analog&RS232 interfaces 15U
IT8090-1500-200 1500V 200A 90kW 0.1V/0.01A ≤0.02%+0.02%FS/≤0.1%+0.1%FS USB/CAN/LAN/digital IO interface, optional GPIB/Analog&RS232 interfaces 27U
IT8108-1500-240 1500V 240A 108kW 0.1V/0.01A ≤0.02%+0.02%FS/≤0.1%+0.1%FS USB/CAN/LAN/digital IO interface, optional GPIB/Analog&RS232 interfaces 27U
IT8126-1500-280 1500V 280A 126kW 0.1V/0.01A ≤0.02%+0.02%FS/≤0.1%+0.1%FS USB/CAN/LAN/digital IO interface, optional GPIB/Analog&RS232 interfaces 27U
IT8144-1500-320 1500V 320A 144kW 0.1V/0.01A ≤0.02%+0.02%FS/≤0.1%+0.1%FS USB/CAN/LAN/digital IO interface, optional GPIB/Analog&RS232 interfaces 27U
IT8018-2250-25 2250V 25A 18kW 0.1V/0.001A ≤0.02%+0.02%FS/≤0.1%+0.1%FS USB/CAN/LAN/digital IO interface, optional GPIB/Analog&RS232 interfaces 3U
IT8036-2250-50 2250V 50A 36kW 0.1V/0.01A ≤0.02%+0.02%FS/≤0.1%+0.1%FS USB/CAN/LAN/digital IO interface, optional GPIB/Analog&RS232 interfaces 6U
IT8054-2250-75 2250V 75A 54kW 0.1V/0.01A ≤0.02%+0.02%FS/≤0.1%+0.1%FS USB/CAN/LAN/digital IO interface, optional GPIB/Analog&RS232 interfaces 15U
IT8072-2250-100 2250V 125A 72kW 0.1V/0.01A ≤0.02%+0.02%FS/≤0.1%+0.1%FS USB/CAN/LAN/digital IO interface, optional GPIB/Analog&RS232 interfaces 15U
IT8108-2250-150 2250V 175A 108kW 0.1V/0.01A ≤0.02%+0.02%FS/≤0.1%+0.1%FS USB/CAN/LAN/digital IO interface, optional GPIB/Analog&RS232 interfaces 27U
IT8126-2250-175 2250V 200A 126kW 0.1V/0.01A ≤0.02%+0.02%FS/≤0.1%+0.1%FS USB/CAN/LAN/digital IO interface, optional GPIB/Analog&RS232 interfaces 27U
IT8144-2250-200 2250V 225A 144kW 0.1V/0.01A ≤0.02%+0.02%FS/≤0.1%+0.1%FS USB/CAN/LAN/digital IO interface, optional GPIB/Analog&RS232 interfaces 27U