LVDS POD
BusFinder Protocol Analyzer
LVDS Probe can be applied to logic signal and low voltage differential signal (LVDS) measureme.
- Threshold:NA (LVDS P/N reference)
- Non-destructive:-0.5V ~ +4.6V
- Operation Voltage:0~3.3V
- Sensitivity=100mV
- Impedance:100kohm || 2pF
- Data rate:500Mbps(250MHz)
- Vid-min:150mV
- Vic (Common):0+Vid/2 ~ 3.3-Vid/2
Introduction:
LVDS Probe is only for LA4000/3000 series & BusFinder series. LVDS Probe can be applied to logic signal and low voltage differential signal(LVDS) measurement.
- LA08/09 Tip: Digital signal input channel. It contains 2 LA09-tip & 1 LA08-tip for single-ended signal measurement.
- LVDS Tip: Low voltage differential signal input channel. It contains 8 pairs of differential signals in the LVDS-tip
LVDS, as a commonly used high-speed data transmission standard, requires dedicated probing tools for signal analysis and measurement. It finds extensive applications in high-speed data transmission systems, image processing, industrial automation, and other fields.
Signal Compatibility:
LVDS logic analyzer probes should exhibit good signal compatibility, capable of adapting to different types and standards of LVDS signals.
Measurement Range:
The probes should cover the typical LVDS signal range, including the general voltage range of 200 mV to 1200 mV, to ensure accurate measurements.
Excellent Common Mode Rejection Ratio (CMRR):
The probes should have excellent CMRR to reduce the impact of common mode interference on measurements, ensuring precise signal analysis.
Differential Acquisition Capability:
The probes should effectively capture LVDS differential signals, maintaining signal integrity and reducing signal distortion.
Low Interference and Noise:
The probes should possess outstanding interference resistance, minimizing external interference and noise”s impact on measurements.
Specifications are as follows:
- Threshold:NA (LVDS P/N reference)
- Input Voltage:Max=0~3.3V
- Sensitivity=100mV
- Impedance:75kohm || 3pF
- Data rate:500Mbps (Same as LA-probe)
Option Model | LVDS Probe |
Tip | LVDS |
Number of Chs | 8-Diff. |
Threshold Range (Data) | – |
Threshold Resolution (Data) | – |
Threshold Accuracy (Data) | – |
Input Voltage Non-destructive Max. (Data) | -0.5V ~ +4.6V DC+AC peak |
Input Voltage Operation (Data) | 0V ~ 3.3V |
Input Voltage Sensitivity (Data) | ~100mV |
Impedance (Data) | 75K Ω || 3pF |
Input Voltage Non-destructive Max. (Analog) | – |
Input Voltage Operation (Analog) | – |
Input Voltage Resolution (Analog) | – |
Input Voltage Sampling Rate (Analog) | – |
Impedance (Analog) | – |