FWM8612

FWM8612

Fast Wavelength Meter

With the growing demand for communication data, it is necessary to have a larger capacity optical communication transmission system, which drives optical component/network equipment manufacturers to use coherent communication modules based on wavelength tunable lasers in their transmission backbone networks. At present, the wavelength tunable lasers and coherent modules will be used in MAN, or even access networks. Accurate measurement and wavelength calibration are crucial for tunable lasers. With the continuous increase of communication channels from the initial 40 waves to the current maximum 800, efficient and accurate wavelength testing is more critical than ever.

Features

10

High Wavelength Accuracy

±0.33ppm (typ: ±0.5pm) for wavelength calibration and metrology

11

Fast Test

All-solid-state structure, non-mechanical moving parts optical design, fast test speed

12

Supports broadband Mode

Accurate wavelength measurement of 96Gbaud modulated optical signals

13

Rich Trigger Function

Supports external or internal trigger

Functions and Advantages

High Speed

The FWM8612 wavelength meter is in the ordinary single sampling mode, the sampling rate can be as high as 200Hz, which is 20-100 times that of the ordinary multi-wavelength based Michelson interferometer, the power accuracy <0.5dB, and the repeatability <0.02dB.

e59a0a9721910462ebb9605edc99bd7d
e1770ba5b79c21cb82a3efc362c4d6b8

Internal Trigger Sampling Mode

FWM8612 has a built-in trigger signal generator, and its fast measurement function, as shown in the figure below, triggers 1000Hz to measure the switching cycle and stability of ordinary mechanical optical switches, and can observe the transient wavelength and power information of the tunable laser.

External Trigger Sampling Mode

FWM8612 fast wavelength meter supports 5V TTL trigger level and external trigger with sampling rate up to 1000Hz. It can simultaneously measure the scanning spectrum of tunable lasers, Mode Map scanning and channel calibration of tunable lasers, and synchronous monitoring of wavelength power of pulsed lasers.

d02a2de95fb3f3a4f8353700efe970dd
caa8b5a03e792344013d2d9cdf0ad6ed

Broadband Working Mode

High-speed modulation will make the original narrow linewidth laser (usually kHz~MHz) spectral broadening (96Gbaud modulation signal)。

Broadband Working Mode

FWM8612 has been further optimized on the basis of the original, and finally realized the accurate wavelength measurement of 400G QAM16 (96Gbaud) signal.

144a21cfabde1aa8d89daa18be818741 png scaled

Instrument Specifications

Wavelength Measurement
Wavelength Range 1250~1650 nm (182~240THz)
Wavelength Accuracy ±0.33 ppm(±0.5pm@1550 nm)
Wavelength Repeatability ±0.07 ppm(±0.1pm@1550 nm)
Wavelength Stability <±0.3pm@24小时
Wavelength Resolution 0.1pm
Unit nm, cm-1, THz
Power Measurement
Calibration Accuracy ±0.5 dB(±30nm from 1310 and 1550 nm)
Linearity ±0.5 dB(1250–1650 nm)
Polarization Dependence ±0.5 dB(1250–1650 nm)
Display Resolution 0.01 dB
Unit dBm, mW
Sampling Rate
Single Sampling Single sample~200 Hz
External Trigger Up to 1000 Hz
Internal Trigger 1~1000 Hz configurable
Triger
Triger Level TTL
External Trigger Wavelength and power synchronized Trigger (1~1000 Hz)
Internal Trigger Internal trigger frequency configurable (1~1000 Hz)
Input Optical Signal
Input Optical Power -30 dBm~+10 dBm

(8 µW~10 mW)

Optical Connector 9/125µm Single mode fiber (FC/PC)

Optional:Single mode fiber(FC/APC)

Optical Connector Return Loss >35 dB
Multi-peak Detection
Minimum frequency separation between main and secondary peaks 2300 MHz
Minimum power separation between main and secondary peaks 17 dB