BI6203

BI6203

CoC Burn-In System

The BI6203 Burn-in System is a high-density, multi-functional testing system specifically designed for the verification of the burn-in lifespan of laser chips. The system adopts a modular design with large single-layer structure. Integrating multi-channel power supplies, temperature controllers, real-time data acquisition capabilities. Standardized drawers and flexible fixture are suitable for various sizes of CoC (Chip on Carrier). The fixtures can be easily replaced to accommodate different device types. Drawers could be replaced when new test functions are added, such as thermistor monitoring and power monitoring.

Features

13
Driving Power Supply

Supports up to 4224 channels of 4-quadrant driving power supply

10
Strong Thermal Conductivity

Temperature deviation < ±1.0℃ for the overall thermal sink(25~100℃)

11
Temperature Control

Each fixture has independent heating, temperature control, monitoring, over temperature protection and heat dissipation units for energy saving

12
Fixture

Fishbone-type fixture which support wire bonding on it

16
Safety and Reliability

Comprehensive protection mechanisms through hardware and software eliminate potential issues such as EOS

17
Online Power Monitoring

Optional configuration for online power monitoring, supporting complete LIV or EA scans, with the ability to analyze Ith. The test repeatability deviation <±1%

24
4224 CoC Simultaneously Burn-in

Production capacity flexibly configured based on customer requirements

15
Software Functions

All test results, test statuses, and abnormal conditions are recorded in the database which could be stored and traced efficiently

Functions and Advantages

Special Temperature Control Structure
with Excellent Thermal Conductivity

CoC, CoS drawer and clamp

BI6202
No. Module Part number Description
1 CoC Burn-in System cabinet (including computer) P09000037 Main frame, computer, software(remark: up to 11 layers)
2 CoC Burn-in System single layer (including Driving board) P02004448 – 96 channels standard driving board

– Switch mode power supply

– Temperature control module

– Backplane

– Cylinder

– CDA N2 control system

3 Burn-in drawer P02004255 – Double fixtures with 96 channel PD

– Drawer temperature range 40~120℃

– G4 long fixture

– Heat sink temperature uniformity ±2℃

FB020313 – Drawer temperature range 40~120℃

– G4 long fixture

– Heat sink temperature uniformity ±2℃

4 Burn-in fixture(including up and bottom fixtures)  C04000223 – Support 48 channel DML CoC
5 Load board 2Ω resistor board