S2022H

8-Channel Precision Source Meter

The S2022H precision source meter is compact and cost-effective bench-top Source/Measure Units (SMUs) with the capability to source and measure both voltage and current. These capabilities make the S2022H ideal for IV (current versus voltage) measurement tasks that require both high resolution and accuracy.

  • High range – Range: ± 30 V, ± 500 mA (DC)
  • High resolution – The minimum measurement resolution can reach 100 pA/100 μV
  • High sampling rate – Supports up to 500k ADC sampling rate
  • Threshold trigger – Hardware high-speed IO, capable of threshold triggering, enabling efficient interaction between output measurement values and user systems

Features and Benefits

I-V output capability

dab2e878b50f02b5dc08cb6806df72ea

Voltage source specifications

Voltage programming accuracy Range Programming Resolution Accuracy (1 year)

± (% reading+offset)

Typical noise (RMS)

0.1 Hz-10 Hz

± 30 V 1  mV 0.03%+4 mV 1000 μV
± 6 V 200 μV 0.03%+1 mV 100 μV
Temperature coefficient ± (0.15 x accuracy)/℃ (0 ℃ -18 ℃, 28 ℃ -50 ℃)
Channel1 CH1 to CH8
Output power Ch1 Ch4: 3W per channel and 6W total
Ch5 Ch8: 3W per channel and 6W total
Setting Time < 200 μs (typical)
Overshoot < ±0.1% (Typical, Normal, Step is 10% to 90%, full range, resistive load)
Noise 10Hz-20MHz 6V voltage source, 0.5A resistive load,< 3 mVrms

 

  1. Channels are isolated from earth ground, but ch1 to ch4 share a common LO. but ch5 to ch8 share a common LO.

Current source specifications

Current programming accuracy Range Programming Resolution Accuracy (1 year)

± (% reading+offset)

Typical noise (RMS)

0.1 Hz-10 Hz

± 500 mA1 20 μA 0.05%+100 μA+  Vo * 25 μA 10 μA
± 100 mA 4  μA 0.05%+10 μA+  Vo * 5 μA 1 μA
± 10 mA 400 nA 0.05%+5 μA+  Vo * 500 nA 100 nA
± 1 mA 40 nA 0.05%+500nA+ Vo * 50 nA 10 nA
± 100 μ A 4  NA 0.05%+50 nA+  Vo * 5 nA 1 nA
± 10 μ A 400 pA 0.05%+20 nA+  Vo * 500 pA 150 pA
Temperature coefficient ± (0.15 x accuracy)/℃ (0 ℃ -18 ℃, 28 ℃ -50 ℃)
Channel2 CH1 to CH8
Output power Ch1 Ch4: 3 W per channel and 6W total

Ch5 Ch8: 3 W per channel and 6W total

Setting Time < 300 μs (typical)
Overshoot < ± 0.1% (Typical, Normal, Step is 10% to 90%, full scale point, resistive load test)

 

  1. 500mA range is available only for 6V voltage range.
  2. Channels are isolated from earth ground, but ch1 to ch4 share a common LO. but ch5 to ch8 share a common LO.

Voltmeter  measurement specifications

Voltage measurement accuracy Range Measurement Resolution Accuracy (1 year)

± (% reading+offset)

± 30 V 300 μV 0.03%+4 mV
± 6 V 60 μV 0.03%+1 mV
Temperature coefficient ± (0.15 x accuracy)/℃ (0 ℃ -18 ℃, 28 ℃ -50 ℃)

Current measurement specifications

Current measurement accuracy Range Measurement Resolution Accuracy (1 year)

± (% reading+offset)

± 500 mA1 10 μA 0.05%+100 μA+  Vo * 25 μA
± 100 mA 1 μA 0.05%+10 μA+  Vo * 5 μA
± 10 mA 100 nA 0.05%+5 μA+  Vo * 500 nA
± 1 mA 10 nA 0.05%+500 NA+  Vo * 50 nA
± 100 μA 1 nA 0.05%+50 NA+  Vo * 5 nA
± 10 μA 100 pA 0.05%+20 NA+  Vo * 500 pA
Temperature coefficient ± (0.15 x accuracy)/℃ (0 ℃ -18 ℃, 28 ℃ -50 ℃)

 

  1. 500mA range is available only for 6V voltage range.

Typical output setting time

Source Range Output setting time Condition
Fast  1, 2 Normal1 Slow1
Voltage 30 V < 400 μs < 1.5ms < 2.8 ms Time required to reach within 0.1 % of final value at open load condition. Step is 10 % to 90 % range
6  V <250 μs <780 μs <2.8 ms
Current ± 500 mA <50 μs <330 μs <2.5 ms Time required to reach within 0.1 % of final value at short condition. Step is 10 % to 90 % range
±100 mA <50 μs <270 μs <2.5 ms
±10 mA <50 μs <270 μs <2.5 ms
±1 mA <100 μs <290 μs <2.5 ms
±100 μA <150 μs <5 ms <2.5 ms
±10 μA <250 μs <3 ms <2.5 ms

 

  1. Output transition speed:Fast, Normal, Slow
  2. Slow mode is recommended for overshoot sensitive equipment, Fast mode may have overshoot on output in some condition