S2019C

S2019C

4-channel PXIe SMU

The S2019C is a high precision, compact, cost-effective, 4-channel PXIe Source/Measure Unit (SMU) with the capability to source and measure both voltage and current. It has maximum ±40 V, ± 500 mA(DC), ±1 A(Pulse) sourcing capability, and supports conventional SCPI commands for easy programming. It supports most standard PXIe chassis and multi-card synchronization. The S2019C can be integrated into production test environment to achieve test efficiency improvement and cost reduction.

Features

10

Easy to Expand

4-channel PXIe SMU, easy to scale out

11

High Range

Range: ± 40 V, ± 500 mA (DC), ±1 A(pulse)

12

High Resolution

The minimum measurement resolution can reach 1 pA/1 μV

13

High Sampling Rate

Up to 1MS/s ADC sampling rate

Functions and Advantages

5 Functions In One Card

Voltage source
Current source
Ammeter
Voltmeter
Electronic load

5 Functions In One Card
Four Quadrants

♦ The first and third quadrants are the source: the actual polarity of output V / I follows the source setting.
♦ The second and fourth quadrants are for load: CC and CV cooperate. When the load is used, the polarity of the load setting is opposite to the source polarity.

Can Test Various Equipment

Can Test Various Equipment
Measurement Data

Capture More Measurement Data

♦ 6.5-digit resolution: Enjoy best-in-class 6.5-digit sourcing and measurement resolution.
♦ 1 pA / 1 μV resolution: excellent measurement sensitivity.
♦ 1 MS/s sampling rate: provide high-speed measurement, and can quickly set / digitize the rate to any waveform generator (list scan).

Rich Scanning Function

Rich Scanning Function

Voltage Source Setting and Measurement Accuracy

Voltage Accuracy
Range Resolution Accuracy(1 year)

±(%RD+mV)[1]

Typical Noise (RMS)

0.1 Hz-10 Hz

±40 V[3] 10μV 0.015%+1.2 mV 50 μV
±6 V 1 μV 0.015%+600 μV 10 μV
Temperature Coefficient ±(0.15×accuracy)/℃(0℃-18℃, 28℃-50℃)
Channel [2] CH0 to CH3
Output Power 4 W per channel and maximum 8 W total
Overshoot <±0.1%( typical, Normal, step is 10% to 90% range,  full range, resistive load)
Noise

10Hz-20MHz

6 V voltage source, 0.5 A resistive load, <3 mVrms

[1] Accuracy calculation example: Testing the accuracy of a 1V output in a 6V range, the allowable tolerance is:6c5ebc5a59f841b3b173264238399d12
[2] All channel outputs are electrically isolated from the ground, but the outputs of each channel share a common ground(LO)
[3] This instrument has a potential danger of high voltage (±42 V) output to the HI/Sense HI/Guard terminals. To prevent electric shock, relevant safety precautions must be taken before powering on. Do not connect the Guard terminal to any output. (Including shorting to the chassis ground or outputLO),otherwise, the instrument will be damaged

Current Source Setting and Measurement Accuracy

Current

Accuracy

Range Resolution Accuracy(1 year)
±(%RD+mA)
Typical Noise (RMS)

0.1Hz-10Hz

±1 A[4][5] 500 nA 0.1% + 125 μA 20 μA
±500 mA[5]
±100 mA 100 nA 0.03% + 25 μA 2 μA
±10 mA 10 nA 0.03% + 2.5 μA 200 nA
±1 mA 1 nA 0.03% + 250 nA 20 nA
±100 μA 100 pA 0.03% + 25 nA 2 nA
±10 μA 10 pA 0.03% + 3 nA 200 pA
±1 μA 1 pA 0.03% + 500 pA 30 pA
Temperature Coefficient ±(0.15×accuracy)/℃(0℃-18℃,28℃-50℃)
Channel CH0 to CH3
Output Power 4 W per channel and maximum 8 W total
Overshoot <±0.1%(typical. normal. step is 10% to 90% range, full range, resistive load)

[4] The 1A range only supports pulse mode, with a typical accuracy
[5] The 1A and 500mA ranges only support a voltage range of 6V