S3023P
High-Voltage Semiconductor Pulse Generator Unit S3023P
Semight S3023P It is a Single-Channel High-Voltage Semiconductor Pulse Generator Unit that can output adjustable high-precision high-voltage pulse sources.
- High voltage range – ±40V,Meet NVM testing technical conditions
- High voltage with fast rate of change – 1000V/us,A high-voltage pulse source that can generate faster edges
- Standard pulse mode – three-level pulse, period:40ns~10s
- Delay adjustable – time:0~9.999s,resolution ratio:2.5ns
- High-speed measurement – 500MS/s,Timely diagnosis of load impedance
- Adjustable pulse count – range:1~100,000个
- Minimum sampling period for voltage detection – 5us
- Level timing trigger – TTLLevel, pulse cycle synchronization
Features and Benefits
Working conditions:
Temperature 23 ℃± 5 ℃
Humidity 30% to 70% relative humidity measure after preheating for 60 minutes, and the ambient temperature change during measurement < ± 3 ° C
Calibration cycle is 1 year
Measurement speed 1 PLC

Pulse or DC output voltage indicators
| Project | Test conditions | Technical indicators | Remarks |
| Voltage amplitude | 50 Ω load | -20V~+20V | |
| Open circuit | -40V~+40V | ||
| Voltage amplitude resolution | 50 Ω load | 0.2mV | |Vout | ≤ 5V |
| 0.8mV | 0.5V ≤ | Vout | ≤ 20V | ||
| open circuit | 0.4mV | | Vout | ≤ 10V | |
| 1.6mV | 10V ≤ | Vout | ≤ 40V | ||
| Output interface | SMA | ||
| Internal resistance | 50 Ω ± 1% | ||
| Output short-circuit current | 800mA peak (400mA mean) | ||
| Output overshoot (ringing) | 50 Ω load | ± (5%+20mV) |
Pulse or DC output voltage indicators (both with 50 Ω terminal load, should be open-loop control indicators, high-speed pulse)
| Project | Sub projects | Technical indicators | Remarks |
| Frequency range | 0.1~33MHz | ||
| Pulse period | Programmable range | 40ns~10s | |
| Resolution | 10ns | ||
| Minimum cycle | 100ns | Vamp ≤ 10V | |
| Accuracy | ± 1% (0.01%+200ps) | ||
| Pulse width | Programmable range | 20ns~(pulse period -10ns) | |
| Resolution | 2.5ns | Vamp< 10V | |
| 20ns | Vamp>10V | ||
| Minimum value (10%~90% edge) | 120ns | ||
| Accuracy | ± (3%+2ns) | ||
| Pulse process time (Tr and Tf) | Programmable range | 20ns~400ms | |
| Resolution | 2ns | Tr+Tf ≤ 10us | |
| 20ns | Tr+Tf>10us | ||
| Minimum value (10%~90% edge) | 30ns | Vamp ≤ 5V | |
| 35ns | Vamp ≤ 10V | ||
| 40ns | Vamp ≤ 20V | ||
| 60ns | Vamp>20V | ||
| Accuracy | -5%~+5%+25ns | Vamp ≤ 10V | |
| -5%~+5%+40ns | Vamp ≤ 20V |
SPGU supplementary indicators
Advanced features:
| Project | Technical indicators | Test conditions |
| Pulse width jitter | 0.001%+150ps | |
| Pulse period jitter | 0.001%+150ps | |
| Maximum voltage swing rate | 1000V/us | Vamp=40V (50 Ω Load) |
| Output noise | 20mVrms | |
| Voltage monitoring | SPGU monitoring and testing unit terminal voltage | |
| Measurement accuracy | ± (0.1%+25mV) | |
| Measurement resolution | 50uV |