LA-POD2

BusFinder Protocol Analyzer

  • The LA-POD2(32Ch) can be used in any slot. It has 4 LA tips.
  • LA4K-tip*2: 8 Data Channel
  • LA4K-tip*2: 8 Data Channel + 1 CLK Channel
  • Operation Voltage: ±15V
  • Timing Analysis: 2.4 GHz
Logic Analyzer (LA) Mode
Support eMMC 5.1, NAND Flash, SD 3.0 (SDIO 3.0), Serial Flash (SPI NAND), SPI Protocol trigger & 100+ Protocol decodes
  • Capture digital waveforms and support bus decodes. Able to stack with a DSO to form as an MSO.
  • Provides multiple storage modes, users could select to have long time recording or precision acquisition.
942dd31fa95cd4edd539a7a040ca8fc2

Long Time Record: Transitional Storage VS Compressed Storage

For signal capture and analysis, usually require to record the signal for a long time. If the data is stored in a compressed way, it will cause your software to lag or even stop functioning when decompressing the data after it is sent back to the computer. Because PC memory size might insufficient for decompressed data size. To satisfy the requirement of smooth software operation and long-term recording without missing any data, the storage method adopted by the Acute analyzer is transitional storage rather than compression. After returning to the PC software, it doesn”t need to do the decompression. The decoded results can be displayed while the analysis is finished.

b9c20799791d6f5da49137a937070467 scaled

Parallel Clause Triggers
16-States parallel IF Clause settings for 128/64 channel value compare combined with AND/OR logic condition and 4 Timer/Counter conditions.

f2db52b81e3e6f581c478cfa4fd1dfa4

Flow chart bus triggers

f8eddda619e5b21e3213f3a4c6a7b04a 2

Power trigger for serial bus, 8-states flow chart setting with Counter/Timer

65ddc5214184dc442f73b2d5cc5ea46d 2 png

Detail parameters for each states

Stack With Other Vendors of Oscilloscope

201258a1cca1428340f13363f955dbb6
e546e34503f48e302bc89f96e1f29700 png
0219a50a50820157e7a7eadcf0e8fceb png

Add Notes & Pictures in Waveform

2a5c64d3fd7833cd02c5bf1139c6d517

Protocol Analyzer (PA) Mode
It is hardware decoding, may log protocol data very long time if without waveforms. Application timing: Preliminary protocol debug.

Protocol Analyzer
Show real-time protocol data. Application timing: massive protocol data with some idles in between.

5aa4936bc2f5b9c72dc773c729802cbf

Protocol Logger
Like data logger, save massive data into SSD hard drive. Application timing: massive protocol data.

b70f9863bb0d6953dc77b5005fda794e

Protocol Monitor
Like dash cameras, record protocol data by the device’s memory only. Application timing: trigger event only happens in very long time.

2d821a50424d3c9d9dbf2532f65dc458
Option Model LA-POD2
Tip LA4K
Number of Chs 8 / 8+1 (Data+CLK)
Threshold Range (Data) ±15V
Threshold Resolution (Data) 10mV
Threshold Accuracy (Data) ±100mV + 5% *Vth
Input Voltage Non-destructive Max. (Data) ±40V DC+AC peak
Input Voltage Operation (Data) ±15V
Input Voltage Sensitivity (Data) ~300mV
Impedance (Data) ~55KΩ || <2pF to 1Vdc
Input Voltage Non-destructive Max. (Analog)
Input Voltage Operation (Analog)
Input Voltage Resolution (Analog)
Input Voltage Sampling Rate (Analog)
Impedance (Analog)