TL4134E Logic Analyzer
TravelLogic Logic Analyzer
• PC-based
• USB3.0 interface
• 34 channels
• 2 GHz Timing / 250MHz State Analysis
• 4Gb Memory
• Stacks with Acute or another DSO to form as an MSO
TravelLogic 4000 series is an upgrade version of TL2000/TL3000. It has improved the memory size and channel counts. And it contains Logic Analyzer Mode and Protocol Analyzer Mode for bus analysis and decodes.
TL4134E can be very helpful to do MIPI I3C packet sniffing. Acute analyzer also offers a MIPI I3C trigger and decode software to debug your MIPI I3C packets by cascading with other brands of oscilloscopes, such as Keysight, R&S, Tektronix, Acute TS series and etc..
MIPI I3C decodes / waveforms:

MIPI I3C Protocol analyzer Report:

Logic Analyzer (LA) Mode
- Capture digital waveforms and support bus decodes. Able to stack with a DSO to form as an MSO.
- Provides multiple storage modes, users could select to have long time recording or precision acquisition.

Long Time Record: Transitional Storage VS Compressed Storage
For signal capture and analysis, usually require to record the signal for a long time. If the data is stored in a compressed way, it will cause your software to lag or even stop functioning when decompressing the data after it is sent back to the computer. Because PC memory size might insufficient for decompressed data size. To satisfy the requirement of smooth software operation and long-term recording without missing any data, the storage method adopted by the Acute analyzer is transitional storage rather than compression. After returning to the PC software, it doesn”t need to do the decompression. The decoded results can be displayed while the analysis is finished.

Flow chart bus triggers
Power trigger for serial bus, 8-states flow chart setting with Counter/Timer

Detail parameters for each states

Stack With Other Vendors of Oscilloscope



Protocol Analyzer (PA) Mode
It is hardware decoding, may log protocol data very long time if without waveforms. Application timing: Preliminary protocol debug.
Protocol Analyzer
Show real-time protocol data. Application timing: massive protocol data with some idles in between.

Protocol Logger
Like data logger, save massive data into SSD hard drive. Application timing: massive protocol data.

Protocol Monitor
Like dash cameras, record protocol data by the device’s memory only. Application timing: trigger event only happens in very long time.

LA Spec. | |
---|---|
Power Source | USB bus-power (+5V) |
Static Power Consumption | 0.8W |
Max Power Consumption | 3W |
Hardware Interface | USB 3.0 |
Timing Analysis (Asynchronous, Max. Sample Rate) | 2GHz |
State Clock Rate (Synchronous, External Clock) | 250MHz |
Storage | Conventional Timing, Transitional Timing |
Channels | 34 |
Total Memory | 4Gb |
Timing Analysis | Available Chs (Conventional / Transitional Timing) – Memory per Ch |
4GHz Timing [Available Chs] – Memory per Ch | N/A |
2GHz Timing [Available Chs] – Memory per Ch | [8/7] – 512Mb |
1GHz Timing [Available Chs] – Memory per Ch | [16/14] – 256Mb |
500MHz Timing [Available Chs] – Memory per Ch | [32/28] – 128Mb |
250MHz Timing [Available Chs] – Memory per Ch | [32/32] – 128Mb |
Channel to channel skew | < 1ns |
Input channels | N/A |
Input impedance | 200KΩ//<7pF |
Max. (Non-destructive) | ±30V DC, 12Vpp AC |
Input operation | ±10V |
Input sensitivity | 0.25Vpp @50MHz, 0.5Vpp @150MHz, 0.8Vpp @250MHz |
Threshold group | 4 (ch0~7, ch8~15 & clk0, ch16~23, ch24~31 & clk1) |
Threshold range | ±5V |
Threshold resolution | 50mV |
Threshold accuracy | ±100mV + 5%*Vth |
Trigger resolution | 500ps |
Trigger types | Channel, Pattern, Single / Multi Level, Width, Time-out, Setup / Hold Timing Violation, External, Manual |
Protocol Trigger | BiSS-C, CAN2.0B/CAN FD, DP_Aux, HID over I2C, I2C, I2S, LIN2.2, MIPI I3C 1.1, SENT, SPI, UART (RS232), USB PD 3 |
Protocol Analyzer | BiSS-C, CAN2.0B/CAN FD, DP_Aux, HID over I2C, I2C, I2S, LIN2.2, MIPI I3C 1.1, SPI, UART (RS232), USB PD 3 |